Sauna heater size calculator
Enter the room. Each maker's own rule for glass and stone turns it into that maker's sizing volume, and each maker's own table says which of its heaters is printed for it. We show them side by side and pick none.
- Harvia KIPHarvia KIP manual: add 1.2 m³ to sauna volume for each m² of non-insulated wall, so a 10 m³ room with a glass door sizes like about 12 m³ 1
Enter your room.
- Harvia CilindroHarvia: each m² of stone, glass or similar non-insulated surface counts as 1.2 m³ of extra room volume 6
Enter your room.
- HUUM DROPHUUM: add 3.3 cu ft of room volume for each 1 sq ft of uninsulated brick, tile or glass wall, or 1 m³ for each 1 m² 12
Enter your room.
- HUUM HIVE, older manual1.5 m³ per m² (about 4.92 cu ft per sq ft) 17
Enter your room.
- HIVE 6 (older table): 6 kW, printed for 5 to 8 m³ 18
Each maker counts cold surfaces its own way, so the same room has a different "calculated" volume for each. We show every maker's answer and pick none. The heater's own manual decides, and HUUM's manual says a wrongly sized heater voids its warranty.
Why there is no single answer
The rule everyone quotes, and the makers' own numbers
You will meet this rule of thumb on dealer pages: Size a sauna heater at 1 kW per 45 to 50 cubic feet Our verdict is Mixed.
HUUM sizes at 1 kW per calculated m³ (about 35.3 cu ft)Manufacturer pageChecked 22 Nov 2026HUUM article, How to dimension a sauna heaterThe calculated volume includes the adders for glass, log and uninsulated walls. The cu ft figure is our unit conversion.Re-check by 22 May 2027Full ledger, and Harvia's support page gives Harvia: on average 1 kW of heater power for each m³ of sauna volumeManufacturer pageChecked 22 Nov 2026Harvia support article "How do I select the correct heater power"An average; Harvia also says to pick a heater near the middle of its own min to max range.Re-check by 22 May 2027Full ledger, before anything is added for glass. One dealer gives 1 kW per 45 cu ft, given as a starting pointSeller pageChecked 22 Nov 2026Sauna Supply Co, choosing the right size heaterA dealer page, not a manual. The same page says the real need depends on glass, insulation and climate, and adds about 1 cu ft per sq ft of glass.Re-check by 22 May 2027Full ledger, and another dealer says 1 kW per 50 cu ft lands at the top of the makers' printed ranges and leaves little or no marginSeller pageChecked 22 Nov 2026Sauna Place sizing guideA dealer page, not a manual. It tells readers to use each heater's printed range rather than any single rule.Re-check by 22 May 2027Full ledger. The chart puts all four in the same unit.
For a 210 cu ft room (6 by 5 by 7 ft, no glass): 5.9 kW by the makers' rule, 4.7 kW by the 45 cu ft rule and 4.2 kW at 50 cu ft. Our arithmetic. Each maker's table, not this division, decides the model.
Glass, stone and log walls
How each maker counts cold surfaces
- 01Harvia
- Harvia: each m² of stone, glass or similar non-insulated surface counts as 1.2 m³ of extra room volumeManufacturer pageChecked 22 Nov 2026Harvia support article "How do I select the correct heater power"Harvia's calculator and manuals apply this; other makers use other figures for the same surfaces.Re-check by 22 May 2027Full ledger. The KIP manual says the same: Harvia KIP manual: add 1.2 m³ to sauna volume for each m² of non-insulated wall, so a 10 m³ room with a glass door sizes like about 12 m³Manufacturer manualChecked 22 Nov 2026Harvia KIP (built-in controls) instructions for installation and use, 6.2 Sauna heater outputGiven in metric only; the manual prints no per square foot figure.Re-check by 22 Nov 2027Full ledger.
- 02HUUM, current US manuals
- HUUM: add 3.3 cu ft of room volume for each 1 sq ft of uninsulated brick, tile or glass wall, or 1 m³ for each 1 m²Manufacturer manualChecked 22 Nov 2026HUUM DROP US manual (H1001L08 v8), Before installationHUUM has published other figures for the same rule (1.5 m³ per m² in older manuals), so the rule depends on which document is read.Re-check by 22 Nov 2027Full ledger. HUUM's sizing article agrees: HUUM article: coefficient k of 1 for glass, log wall or other non-insulated surface, so each m² adds 1 m³Manufacturer pageChecked 22 Nov 2026HUUM article "How to dimension a sauna heater", coefficient tableThe page says the coefficient applies per square foot or meter, but a factor of 1 only works in metric units.Re-check by 22 May 2027Full ledger.
- 03HUUM, older documents still online
- An older HIVE manual adds 1.5 m³ per m² (about 4.92 cu ft per sq ft)Manufacturer manualChecked 22 Nov 2026HUUM HIVE installation manual, older edition hosted by a retailerAn older edition. HUUM's current US manuals and its sizing article use 1 m³ per m², so HUUM's documents disagree. The manual states that a wrongly sized heater voids the warranty.Re-check by 22 Nov 2027Full ledger, and a dealer sizing sheet titled for HUUM says Sizing Your HUUM sheet: add 4.92 cu ft to room volume for each sq ft of glass, tile, brick, concrete or stone, excluding the doorSeller pageChecked 22 Nov 2026Sizing Your HUUM 2023 one-page sheet (HUUM branded, hosted on a retailer Shopify CDN)Authorship is not stated and the sheet is not on a HUUM domain; 4.92 cu ft per sq ft equals 1.5 m³ per m², not the 1 m³ in HUUM's current manuals.Re-check by 22 May 2027Full ledger. Both add more than HUUM's current manuals. The calculator shows the older rule as its own line so you can see the gap.
- 04Log walls
- Harvia gives two methods. Its support page: Harvia support: for non-insulated log interior walls the factor is 1.5Manufacturer pageChecked 22 Nov 2026Harvia support article "How do I select the correct heater power"Read in context this is a per m² factor like the 1.2 for glass, while Harvia's US manuals instead multiply the whole room volume by 1.5.Re-check by 22 May 2027Full ledger. Its US manual: Harvia US manual: multiply the room volume of a log sauna by 1.5 before choosing heater outputManufacturer manualChecked 22 Nov 2026Harvia Cilindro Owner's / Operator's Manual USA, 2.3 Heater OutputA whole-room multiplier, which differs from the per m² log factor on Harvia's support page.Re-check by 22 Nov 2027Full ledger. The calculator does not apply either; if your walls are bare logs, follow your heater's manual.
The tables
Each maker's table, as printed
Every row below is one line of the maker's manual, read on 22 Nov 2026. Room ranges overlap between models, so a room can fit two heaters; the manual's minimum matters as much as its maximum.
| Model | Power | Room | Room (m³) | Current | Cable |
|---|---|---|---|---|---|
| KIP-30 | 3 kWManufacturer manualChecked 22 Nov 2026Harvia KIP (built-in controls) instructions for installation and use, 5.3 SpecificationsThe manual gives current and cable size but no breaker rating; the electrician sizes the breaker to code.Re-check by 22 Nov 2027Full ledger | 84 to 130 cu ft | 2.4 to 3.7 m³ | 12.5 A | 12/2 cable |
| KIP-45 | 4.5 kWManufacturer manualChecked 22 Nov 2026Harvia KIP (built-in controls) instructions for installation and use, 5.3 SpecificationsThe manual gives current and cable size but no breaker rating; the electrician sizes the breaker to code.Re-check by 22 Nov 2027Full ledger | 100 to 210 cu ft | 2.8 to 6 m³ | 18.8 A | 10/2 cable |
| KIP-60 | 6 kWManufacturer manualChecked 22 Nov 2026Harvia KIP (built-in controls) instructions for installation and use, 5.3 SpecificationsThe manual gives current and cable size but no breaker rating; the electrician sizes the breaker to code.Re-check by 22 Nov 2027Full ledger | 170 to 300 cu ft | 4.8 to 8.5 m³ | 25 A | 10/2 cable |
| KIP-80 | 8 kWManufacturer manualChecked 22 Nov 2026Harvia KIP (built-in controls) instructions for installation and use, 5.3 SpecificationsThe manual gives current and cable size but no breaker rating; the electrician sizes the breaker to code.Re-check by 22 Nov 2027Full ledger | 250 to 425 cu ft | 7.1 to 12 m³ | 33.3 A | 8/2 cable |
| Model | Power | Room | Room (m³) |
|---|---|---|---|
| Cilindro 6 | 6 kWManufacturer manualChecked 22 Nov 2026Harvia Cilindro Owner's / Operator's Manual USA, Table 2Assumes a well insulated room with wood-paneled walls and ceiling; glass, stone or log walls need a larger calculated volume.Re-check by 22 Nov 2027Full ledger | 141 to 294 cu ft | 4 to 8 m³ |
| Cilindro 6.8 | 6.8 kWManufacturer manualChecked 22 Nov 2026Harvia Cilindro Owner's / Operator's Manual USA, Table 2Assumes a well insulated room with wood-paneled walls and ceiling; glass, stone or log walls need a larger calculated volume.Re-check by 22 Nov 2027Full ledger | 141 to 354 cu ft | 4 to 10 m³ |
| Cilindro 8 | 8 kWManufacturer manualChecked 22 Nov 2026Harvia Cilindro Owner's / Operator's Manual USA, Table 2Assumes a well insulated room with wood-paneled walls and ceiling; glass, stone or log walls need a larger calculated volume.Re-check by 22 Nov 2027Full ledger | 141 to 431 cu ft | 4 to 12 m³ |
| Cilindro 9 | 9 kWManufacturer manualChecked 22 Nov 2026Harvia Cilindro Owner's / Operator's Manual USA, Table 2Assumes a well insulated room with wood-paneled walls and ceiling; glass, stone or log walls need a larger calculated volume.Re-check by 22 Nov 2027Full ledger | 141 to 494 cu ft | 4 to 14 m³ |
| Cilindro 10.5 | 10.5 kWManufacturer manualChecked 22 Nov 2026Harvia Cilindro Owner's / Operator's Manual USA, Table 2Assumes a well insulated room with wood-paneled walls and ceiling; glass, stone or log walls need a larger calculated volume.Re-check by 22 Nov 2027Full ledger | 141 to 636 cu ft | 4 to 18 m³ |
| Model | Power | Room | Room (m³) | Current | Breaker | Wire |
|---|---|---|---|---|---|---|
| DROP 4 | 4.5 kWManufacturer manualChecked 22 Nov 2026HUUM DROP US installation and operation manual (H1001L08 v8), Table 2 (240 V)Room range assumes insulated walls; add the maker's cold-surface volume first, and the electrician sizes the circuit to local code.Re-check by 22 Nov 2027Full ledger | 106 to 248 cu ft | 3 to 7 m³ | 18.75 A | 30 A breaker | 10 AWG |
| DROP 6 | 6 kWManufacturer manualChecked 22 Nov 2026HUUM DROP US installation and operation manual (H1001L08 v8), Table 2 (240 V)Room range assumes insulated walls; add the maker's cold-surface volume first, and the electrician sizes the circuit to local code.Re-check by 22 Nov 2027Full ledger | 177 to 318 cu ft | 5 to 9 m³ | 25 A | 30 A breaker | 10 AWG |
| DROP 7 | 7.5 kWManufacturer manualChecked 22 Nov 2026HUUM DROP US installation and operation manual (H1001L08 v8), Table 2 (240 V)Room range assumes insulated walls; add the maker's cold-surface volume first, and the electrician sizes the circuit to local code.Re-check by 22 Nov 2027Full ledger | 248 to 389 cu ft | 7 to 11 m³ | 31.25 A | 40 A breaker | 8 AWG |
| DROP 9 | 9 kWManufacturer manualChecked 22 Nov 2026HUUM DROP US installation and operation manual (H1001L08 v8), Table 2 (240 V)Room range assumes insulated walls; add the maker's cold-surface volume first, and the electrician sizes the circuit to local code.Re-check by 22 Nov 2027Full ledger | 283 to 460 cu ft | 8 to 13 m³ | 37.5 A | 50 A breaker | 8 AWG |
| Model | Power | Room | Current | Wire |
|---|---|---|---|---|
| Designer 4.5 | 4.5 kWManufacturer manualChecked 22 Nov 2026Finnleo Designer SL2 heater installation and operating instructions (72-0130), Diagram 2Minimum volume is quoted at a 74 inch wall height and maximum at 96 inches; the chart gives no breaker size.Re-check by 22 Nov 2027Full ledger | 100 to 210 cu ft | 18.8 A | 10 AWG |
| Designer 6.0 | 6.0 kWManufacturer manualChecked 22 Nov 2026Finnleo Designer SL2 heater installation and operating instructions (72-0130), Diagram 2Minimum volume is quoted at a 74 inch wall height and maximum at 96 inches; the chart gives no breaker size.Re-check by 22 Nov 2027Full ledger | 175 to 310 cu ft | 25 A | 10 AWG |
| Designer 8.0 | 8.0 kWManufacturer manualChecked 22 Nov 2026Finnleo Designer SL2 heater installation and operating instructions (72-0130), Diagram 2Minimum volume is quoted at a 74 inch wall height and maximum at 96 inches; the chart gives no breaker size.Re-check by 22 Nov 2027Full ledger | 250 to 425 cu ft | 33.3 A | 8 AWG |
One more line from the makers: Harvia Cilindro PC90E (HPCS9U1HUL): certificate ETL, room volume 141 to 494 cu ftManufacturer pageChecked 22 Nov 2026Harvia US product page, Cilindro PC90E 9,0 kW 240 VAC Steel (HPCS9U1HUL)Gives the mark only; no ETL file or control number is printed.Re-check by 22 May 2027Full ledger. A US product page can print a different range from a European one for a heater with a similar name, so read the manual for the model number on your box.
What this calculator does not do
- Wood-burning stoves are sized by their own makers in other ways; none is here.
- Outdoor barrels with no insulation lose more heat than an insulated room. No maker table we read gives a figure for that, so we add none.
- Warranty: HUUM's older manual says a wrongly sized heater voids the warranty, and HUUM's current terms tie cover to a licensed electrician's install. HUUM: electric heaters carry a 3 year warranty for private use and 1 year for commercial use, heating elements excludedManufacturer pageChecked 22 Nov 2026HUUM Limited Warranty Terms and Conditions v4 (linked from huumsauna.com/warranty), Products and Warranty Period tableHeating elements are excluded (clause 5.1) and coverage needs a licensed electrician's install.Re-check by 22 May 2027Full ledger.
- Electrical: a bigger heater draws more current. See what each heater asks of your panel, or compare the two biggest makers in HUUM vs Harvia.
No merchant links on this page. Our affiliate applications are pending, and we add a link only after a programme approves us and pays in your country. Until then nothing here earns us money. See every programme and its status.
AUDIT TRAILSources used in this calculator
- Harvia KIP US manual: non-insulated wall adder
"Add 1,2 m³ to the volume of the sauna for each non-insulated wall square meter. For example, a 10 m³ sauna room with a glass door has an equal output requirement of about a 12 m³ sauna room."
Limit: Given in metric only; the manual prints no per square foot figure. - Harvia KIP KIP-30-B1: power, room volume and supply (240 V)
"KIP-30-B1/B3 KIP-45-B1/B3 KIP-60-B1/B3 KIP-80-B1/B3 Power (kW) 3.0 4.5 6.0 8.0 240 V 1 Phase (B1) Operating voltage 208 V 3 Phase (B3) Frequency (Hz) 50 / 60 12.5 (B1) 18.8 (B1) 25.0 (B1) 33.3 (B1) Current (A) 8.3 (B3) 12.5 (B3) 16.7 (B3) 22.2 (B3) 12/2 (B1) 10/2 (B1) 10/2 (B1) 8/2 (B1) Cable size 14/3 (B3) 14/3 (B3) 12/3 (B3) 10/3 (B3) Storage temperature 0-50°C / 32-122°F SAUNA STONES Size of stones Ø 5-10 cm / 2-4” Quantity of stones 20 kg / 44 lbs SAUNA ROOM 1900 mm / 75’’ (USA) Room height, min. 1980 mm / 78’’ (Canada) Floor area, min. 1 m2 / 10 ft2 1.5 m2 / 16 ft2 2.6 m2 / 28 ft2 3.7 m2 / 40 ft2 Floor area, max. 2 m2 / 20 ft2 2.8 m2 / 30 ft2 3.7 m2 / 40 ft2 6 m2 / 65 ft2 Room volume, min. 2.4 m3 / 84 ft3 2.8 m3 / 100 ft3 4.8 m3 / 170 ft3 7.1 m3 / 250 ft3 Room volume, max. 3.7 m3 / 130 ft3 6 m3 / 210 ft3 8.5 m3 / 300 ft3 12 m3 / 425 ft3"
Limit: The manual gives current and cable size but no breaker rating; the electrician sizes the breaker to code. - Harvia KIP KIP-45-B1: power, room volume and supply (240 V)
"KIP-30-B1/B3 KIP-45-B1/B3 KIP-60-B1/B3 KIP-80-B1/B3 Power (kW) 3.0 4.5 6.0 8.0 240 V 1 Phase (B1) Operating voltage 208 V 3 Phase (B3) Frequency (Hz) 50 / 60 12.5 (B1) 18.8 (B1) 25.0 (B1) 33.3 (B1) Current (A) 8.3 (B3) 12.5 (B3) 16.7 (B3) 22.2 (B3) 12/2 (B1) 10/2 (B1) 10/2 (B1) 8/2 (B1) Cable size 14/3 (B3) 14/3 (B3) 12/3 (B3) 10/3 (B3) Storage temperature 0-50°C / 32-122°F SAUNA STONES Size of stones Ø 5-10 cm / 2-4” Quantity of stones 20 kg / 44 lbs SAUNA ROOM 1900 mm / 75’’ (USA) Room height, min. 1980 mm / 78’’ (Canada) Floor area, min. 1 m2 / 10 ft2 1.5 m2 / 16 ft2 2.6 m2 / 28 ft2 3.7 m2 / 40 ft2 Floor area, max. 2 m2 / 20 ft2 2.8 m2 / 30 ft2 3.7 m2 / 40 ft2 6 m2 / 65 ft2 Room volume, min. 2.4 m3 / 84 ft3 2.8 m3 / 100 ft3 4.8 m3 / 170 ft3 7.1 m3 / 250 ft3 Room volume, max. 3.7 m3 / 130 ft3 6 m3 / 210 ft3 8.5 m3 / 300 ft3 12 m3 / 425 ft3"
Limit: The manual gives current and cable size but no breaker rating; the electrician sizes the breaker to code. - Harvia KIP KIP-60-B1: power, room volume and supply (240 V)
"KIP-30-B1/B3 KIP-45-B1/B3 KIP-60-B1/B3 KIP-80-B1/B3 Power (kW) 3.0 4.5 6.0 8.0 240 V 1 Phase (B1) Operating voltage 208 V 3 Phase (B3) Frequency (Hz) 50 / 60 12.5 (B1) 18.8 (B1) 25.0 (B1) 33.3 (B1) Current (A) 8.3 (B3) 12.5 (B3) 16.7 (B3) 22.2 (B3) 12/2 (B1) 10/2 (B1) 10/2 (B1) 8/2 (B1) Cable size 14/3 (B3) 14/3 (B3) 12/3 (B3) 10/3 (B3) Storage temperature 0-50°C / 32-122°F SAUNA STONES Size of stones Ø 5-10 cm / 2-4” Quantity of stones 20 kg / 44 lbs SAUNA ROOM 1900 mm / 75’’ (USA) Room height, min. 1980 mm / 78’’ (Canada) Floor area, min. 1 m2 / 10 ft2 1.5 m2 / 16 ft2 2.6 m2 / 28 ft2 3.7 m2 / 40 ft2 Floor area, max. 2 m2 / 20 ft2 2.8 m2 / 30 ft2 3.7 m2 / 40 ft2 6 m2 / 65 ft2 Room volume, min. 2.4 m3 / 84 ft3 2.8 m3 / 100 ft3 4.8 m3 / 170 ft3 7.1 m3 / 250 ft3 Room volume, max. 3.7 m3 / 130 ft3 6 m3 / 210 ft3 8.5 m3 / 300 ft3 12 m3 / 425 ft3"
Limit: The manual gives current and cable size but no breaker rating; the electrician sizes the breaker to code.Another source disagrees: KIP60B: 169 to 300 cu ft, fuse min. 25 A, 10 AWG. Harvia US product page JC60B2401. - Harvia KIP KIP-80-B1: power, room volume and supply (240 V)
"KIP-30-B1/B3 KIP-45-B1/B3 KIP-60-B1/B3 KIP-80-B1/B3 Power (kW) 3.0 4.5 6.0 8.0 240 V 1 Phase (B1) Operating voltage 208 V 3 Phase (B3) Frequency (Hz) 50 / 60 12.5 (B1) 18.8 (B1) 25.0 (B1) 33.3 (B1) Current (A) 8.3 (B3) 12.5 (B3) 16.7 (B3) 22.2 (B3) 12/2 (B1) 10/2 (B1) 10/2 (B1) 8/2 (B1) Cable size 14/3 (B3) 14/3 (B3) 12/3 (B3) 10/3 (B3) Storage temperature 0-50°C / 32-122°F SAUNA STONES Size of stones Ø 5-10 cm / 2-4” Quantity of stones 20 kg / 44 lbs SAUNA ROOM 1900 mm / 75’’ (USA) Room height, min. 1980 mm / 78’’ (Canada) Floor area, min. 1 m2 / 10 ft2 1.5 m2 / 16 ft2 2.6 m2 / 28 ft2 3.7 m2 / 40 ft2 Floor area, max. 2 m2 / 20 ft2 2.8 m2 / 30 ft2 3.7 m2 / 40 ft2 6 m2 / 65 ft2 Room volume, min. 2.4 m3 / 84 ft3 2.8 m3 / 100 ft3 4.8 m3 / 170 ft3 7.1 m3 / 250 ft3 Room volume, max. 3.7 m3 / 130 ft3 6 m3 / 210 ft3 8.5 m3 / 300 ft3 12 m3 / 425 ft3"
Limit: The manual gives current and cable size but no breaker rating; the electrician sizes the breaker to code. - Harvia support: stone or glass surface adder
"One square meter of stone, glass or similar non-insulated surface increases the heater power requirement as much as if the sauna room volume were increased by 1.2 cubic meters."
Limit: Harvia's calculator and manuals apply this; other makers use other figures for the same surfaces. - Harvia Cilindro HPCS6U1H: power and room volume
"HPCS6U1H 6,0 37,5 17 200 90 141 4 294 8 23 47 75 1900"
Limit: Assumes a well insulated room with wood-paneled walls and ceiling; glass, stone or log walls need a larger calculated volume. - Harvia Cilindro HPCS7U1H: power and room volume
"HPCS7U1H 6,8 37,5 17 200 90 141 4 354 10 23 57 75 1900"
Limit: Assumes a well insulated room with wood-paneled walls and ceiling; glass, stone or log walls need a larger calculated volume. - Harvia Cilindro HPCS8U1H: power and room volume
"HPCS8U1H 14/13/40 8,0 37,5 17 200 90 141 4 431 12 23 69 75 1900"
Limit: Assumes a well insulated room with wood-paneled walls and ceiling; glass, stone or log walls need a larger calculated volume. - Harvia Cilindro HPCS9U1H (PC90E): power and room volume
"HPCS9U1H 9,0 37,5 17 200 90 141 4 494 14 23 79 75 1900"
Limit: Assumes a well insulated room with wood-paneled walls and ceiling; glass, stone or log walls need a larger calculated volume.Another source disagrees: Cilindro PC90: 8 to 14 m³. Harvia support article "How do I select the correct heater power" (EU model example). - Harvia Cilindro HPCS11U1H: power and room volume
"HPCS11U1H 16/15/45 10,5 46,3 21 265 120 141 4 636 18 23 98 78 1980"
Limit: Assumes a well insulated room with wood-paneled walls and ceiling; glass, stone or log walls need a larger calculated volume. - HUUM rule for uninsulated brick, tile or glass walls (current US manuals)
"In case there are any uninsulated brick, tile, or glass walls in the sauna room, an additional 3.3 ft³ must be added to the sauna room volume for each 1 ft² of such wall; or 1 m³ for each 1 m²."
Limit: HUUM has published other figures for the same rule (1.5 m³ per m² in older manuals), so the rule depends on which document is read.Another source disagrees: 53 cu ft (1.5 m³) per m² of uninsulated wall. Older HUUM HIVE manual PDF hosted on a retailer Shopify CDN.Another source disagrees: 4.92 cu ft per sq ft of cold surface. Sizing Your HUUM 2023 sheet on a retailer Shopify CDN.Another source disagrees: coefficient k of 1 per m² of glass or log wall. HUUM article on dimensioning a sauna heater. - HUUM DROP 4: power, room volume and circuit (240 V)
"106-248 ft3 DROP 4 4.5 3–7 m3 18.75 30 10"
Limit: Room range assumes insulated walls; add the maker's cold-surface volume first, and the electrician sizes the circuit to local code. - HUUM DROP 6: power, room volume and circuit (240 V)
"177-318 ft3 DROP 6 6 5–9 m3 25 30 10"
Limit: Room range assumes insulated walls; add the maker's cold-surface volume first, and the electrician sizes the circuit to local code. - HUUM DROP 7: power, room volume and circuit (240 V)
"248-389 ft3 DROP 7 7.5 7–11 m3 31.25 40 8"
Limit: Room range assumes insulated walls; add the maker's cold-surface volume first, and the electrician sizes the circuit to local code. - HUUM DROP 9: power, room volume and circuit (240 V)
"283-460 ft3 DROP 9 9 8–13 m3 37.5 50 8"
Limit: Room range assumes insulated walls; add the maker's cold-surface volume first, and the electrician sizes the circuit to local code.Another source disagrees: DROP 9: 9 kW for 282 to 530 cu ft (8 to 15 m³), 50 A breaker, 6 AWG. Older HUUM DROP manual PDF hosted on a retailer Shopify CDN (shop 21798295), Tables 1 and 2. - Older HUUM HIVE manual (a retailer-hosted copy): extra room volume per square metre of uninsulated glass, brick or tile
"In case there are any uninsulated brick, tile or glass walls in the sauna room, an additional volume of 53 ft³ (1.5 m³) should be added to the sauna room for each such square meter of the wall."
Limit: An older edition. HUUM's current US manuals and its sizing article use 1 m³ per m², so HUUM's documents disagree. The manual states that a wrongly sized heater voids the warranty.Another source disagrees: 1 m³ per m² (coefficient k = 1). HUUM article, How to dimension a sauna heater.Another source disagrees: 3.3 cu ft per sq ft, or 1 m³ per m². HUUM DROP US user manual (2026). - HUUM HIVE 6 electric heater: power, room volume and supply
"HIVE 6 6 176.6-282 ft3 2 25 30 10 [...] 5-8 m3"
Limit: Read from the PDF as text. The HIVE 9 row of the same table did not extract cleanly and is not used. The manual requires a certified electrician. - Finnleo Designer 4.5 (1712-45-0207): power, room volume and wire (240 V, 1 phase)
"Heater 4.5 1 240 18.8 2 #10AWG+GR 2 #10AWG+GR 4.5 12 sq. ft. 74" 100 96" 210"
Limit: Minimum volume is quoted at a 74 inch wall height and maximum at 96 inches; the chart gives no breaker size. - Finnleo Designer 6.0 (1712-60-0207): power, room volume and wire (240 V, 1 phase)
"Heater 6.0 1 240 25 2 #10AWG+GR 2 #10AWG+GR 6.0 21 sq. ft. 74" 175 96" 310"
Limit: Minimum volume is quoted at a 74 inch wall height and maximum at 96 inches; the chart gives no breaker size. - Finnleo Designer 8.0 (1712-80-0207): power, room volume and wire (240 V, 1 phase)
"Heater 8.0 1 240 33.3 2 #8AWG+GR 2 #8AWG+GR 8.0 31 sq. ft. 74" 250 96" 425"
Limit: Minimum volume is quoted at a 74 inch wall height and maximum at 96 inches; the chart gives no breaker size. - HUUM sizing rule
"One calculated cubic meter presumes one kilowatt of the heater’s power."
Limit: The calculated volume includes the adders for glass, log and uninsulated walls. The cu ft figure is our unit conversion. - Harvia support: heater power per cubic meter
"An average of 1 kW of heater power is required for each cubic meter of sauna volume (1 m³ = 1 kW)."
Limit: An average; Harvia also says to pick a heater near the middle of its own min to max range. - Dealer rule of thumb for heater size
"The basic math everyone throws around is 1 kilowatt per 45 cubic feet. That’s your starting point, but it’s just that – a starting point."
Limit: A dealer page, not a manual. The same page says the real need depends on glass, insulation and climate, and adds about 1 cu ft per sq ft of glass.Another source disagrees: 1 kW per calculated m³ (about 35.3 cu ft). HUUM article, How to dimension a sauna heater. - What one dealer says about the 1 kW per 50 cu ft rule
"A 1 kW per 50 cubic feet rule lands at the top of those ranges (for example, the HUUM DROP 9 tops out at 460 ft³ and the Harvia KIP 45 at 210 ft³), so it leaves little or no margin."
Limit: A dealer page, not a manual. It tells readers to use each heater's printed range rather than any single rule. - HUUM article: coefficient for non-insulated surfaces
"In order to determine the additional volume of non-insulated surfaces (VS), multiply the square feet/meter of non-insulated surfaces (S) by the corresponding coefficient (k). | Non-insulated surface | Coefficient (k) | |---|---| | Glass, log wall or other non-insulated surface | 1 |"
Limit: The page says the coefficient applies per square foot or meter, but a factor of 1 only works in metric units. - Sizing Your HUUM sheet: cold surface adder
"For each square foot of cold surface materials (excluding door), an additional 4.92 cubic feet must be added to the total room volume calculation."
Limit: Authorship is not stated and the sheet is not on a HUUM domain; 4.92 cu ft per sq ft equals 1.5 m³ per m², not the 1 m³ in HUUM's current manuals. - Harvia support: non-insulated log wall factor
"If the interior walls of the sauna room are made of non-insulated logs, the corresponding factor is 1.5."
Limit: Read in context this is a per m² factor like the 1.2 for glass, while Harvia's US manuals instead multiply the whole room volume by 1.5.Another source disagrees: multiply the room volume of a log sauna by 1.5. Harvia Cilindro Owner's / Operator's Manual USA, 2.3 Heater Output. - Harvia US manuals: log sauna volume multiplier
"Because log walls are heated slowly, the cu- bic volume of a log sauna should be multi- plied by 1.5, and the heater output should then be selected on the basis of this information."
Limit: A whole-room multiplier, which differs from the per m² log factor on Harvia's support page. - Harvia Cilindro PC90E US page: certificate and room range
"HPCS9U1HUL Type code PC90E Room volume 141 - 494 ft³ Certificates ETL"
Limit: Gives the mark only; no ETL file or control number is printed. - HUUM warranty period for electric heaters
"Electrical heaters 3 years 1 year"
Limit: Heating elements are excluded (clause 5.1) and coverage needs a licensed electrician's install.Another source disagrees: claims may be made up to 5 years after purchase. Older HUUM HIVE manual PDF hosted on a retailer Shopify CDN, Warranty section.